Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
Decontamination of Customized Laser-Microtextured Titanium Abutments: A Comparative in Vitro Study of Different Cleaning Procedures
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 38 , Issue 5
September/October 2018

Pages e87–e95


Decontamination of Customized Laser-Microtextured Titanium Abutments: A Comparative in Vitro Study of Different Cleaning Procedures


Davide Farronato, DDS, PhD, PD, AP/Davide Fumagalli, DDS/Farah Asa’ad, BDS, MSc, PhD/Giulio Rasperini, DDS


PMID: 29677228
DOI: 10.11607/prd.3250

The aim of this study was to evaluate different cleaning procedures for customized laser-microtextured titanium abutments. A total of 20 customized laser-microtextured abutments were randomized into four groups: no cleaning (control group), ultrasonic treatments + autoclave cycle (group 1), ultrasonic treatments + argon plasma (group 2), and only argon plasma (group 3). Surface contaminants were assessed through scanning electron microscopy and energy-dispersive x-ray spectroscopy microanalysis. In the control group, 99.96% of the abutment surfaces were contaminated with organic and inorganic pollutants. Group 3 showed the second highest contamination percentage, with almost 23% of the analyzed surfaces polluted. Samples in groups 1 and 2 were almost clean, with negligible traces of microparticles (0.009% and 0.047% of the surfaces were contaminated, respectively). These results were statistically significant for differences between control and test groups, and between groups 1 and 2 in comparison to 3 (P < .001). Abutment decontamination with argon plasma alone might not be as effective on laser-microtextured surfaces as other cleaning protocols.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 